PMDF Installation Guide
OpenVMS Edition


Previous Contents Index


Chapter 20
PMDF-XGS Transport Bridge Example Installation and Configuration

Example 20-1 shows the installation and configuration of the PMDF-XGS transport bridge component on the OS/2 system known as bridge.example.com (at the TCP/IP level from the PMDF side) and PMDF (as a pseudo-SNADS node from the SNADS side) at the example.com site pictured in Figure 22-1. The example assumes that the CD-ROM drive is drive D:.

Example 20-2 shows a similar installation and configuration on an NT PMDF-XGS transport bridge system. The example assumes that the CD-ROM drive is drive D:.

Remember that the values in this sample are for purposes of example only. Be sure to use the values appropriate for your system when you perform the actual configuration.

Example 20-1 Example PMDF-XGS OS/2 Transport Bridge Installation and Configuration

[D:\other\os2\xgs]install.cmd
PMDF / SNADS server installation 
 
Where do you want the code installed [C:\XGS]? C:\XGS
 
[D:\other\os2\xgs]xcopy *.* c:\xgs 
 
Source files are being read... 
 
D:\other\os2\xgs\aestr32.dll 
D:\other\os2\xgs\appcfns.dll 
D:\other\os2\xgs\config.cmd 
D:\other\os2\xgs\cpicapc.dll 
D:\other\os2\xgs\diaprf32.dll 
D:\other\os2\xgs\gds32.dll 
D:\other\os2\xgs\install.cmd 
D:\other\os2\xgs\readme 
D:\other\os2\xgs\recvsrv.exe 
D:\other\os2\xgs\sendsrv.exe 
D:\other\os2\xgs\xcontrol.exe 
 
11 file(s) copied. 
 
 
[D:\other\os2\xgs\]c: 
 
[D:\other\os2\xgs\]cd  c:\xgs 
PMDF / SNADS server configuration tool 
 
configuring control element 
 
The active components need to introduce themselves to the SNMP control process 
on some TCP/IP port. 
What port is to be used [9990]? 9990 
The control process needs an SNMP community name to register the 
Gateway MIB. 
What community name is going to be used [public]? public
One or more SNADS receive processes may be configured 
How many receive processes should be run [1]? 1
The receive processes need to connect to the PMDF MTA 
What is the TCP/IP hostname of the machine running PMDF? 
naples.example.com
What port is the SNADS receive process on the PMDF machine listening on 
Port number [9993]? 9993
What is the SNADS name of the Gateway? PMDF
What is the maximum document size to be accepted by the Gateway [10000000]? 10000
000 
What is the TCP/IP host name of the syslog host [localhost]? localhost
What directory is to be used to store captured SNADS distributions [.\capture]? 
.\capture 
There may be several SNADS send processes.  Each listens on a separate port 
and is typically used to send to a different SNADS node. 
What port number should the first SNADS send process use [9994]? 9994
What port number should the next SNADS send process use? 
(press enter to end) 
 
 make sure that c:\xgs is added to the LIBPATH path in config.sys 
 
 
[C:\other\os2\xgs] 

Example 20-2 Example PMDF-XGS NT Transport Bridge Installation and Configuration

C:\>md xgs
C:\>cd xgs
C:\xgs>copy D:\other\nt-intel\xgs\*.*
       3 file(s) copied 
C:\xgs>config.bat
PMDF / SNADS server configuration tool 
 
One or more SNADS receive processes may be configured 
How many receive processes should be run [1]? 1
The receive processes need to connect to the PMDF MTA 
What is the TCP/IP hostname of the machine running PMDF? 
naples.example.com
What port is the SNADS receive process on the PMDF machine listening on 
Port number [9993]? 9993
What is the SNADS name of the Gateway? PMDF 
What is the maximum document size to be accepted by the Gateway 
[10000000]? 10000000
What is the TCP/IP host name of the syslog host []? localhost
There may be several SNADS send processes.  Each listens on a separate port 
and is typically used to send to a different SNADS node. 
Only one is needed.  Just press enter to finish the list 
 
What port number should the first SNADS send process use [9994]? 9994
What port number should the next SNADS send process use? [ENTER]
C:\xgs> 


Previous Next Contents Index